Send us a case
To be usable, the examination must meet these requirements:
- Wide-detector scanner, with whole heart acquired simultaneously in a single rotation.
- Helical acquisitions with table motion, even if at low pitch, including dual-source, are not suitable.
- Contrast opacification measurable along the vessel, with a healthy coronary reference segment downstream of the plaque.
- Original DICOM images, thin slices, no processing that alters Hounsfield values.
- Resting systolic and diastolic blood pressure and resting heart rate of the patient, measured before any beta blocker or nitrate. Values recorded during the examination must not be reported.
- Examination performed after administration of sublingual nitrate.
Before sending any image, write to info@virtualstentflow.it with your scanner model and acquisition mode. If the examination is suitable for simulation, we will tell you how to send it securely. Images must be fully anonymized.
Write to usExperimental use only. The result has no clinical value and does not replace invasive functional assessment or clinical judgement.